Laboratory Bio Air Sampler 100L / Min Unique Structure Sampling By Low Noise Pump

China Suzhou Indair indoor air technology co.,ltd certification
China Suzhou Indair indoor air technology co.,ltd certification
Thanks very much for your professional service and kind support during the project. Indair is really a excellent factory in clean room field and help us a lot in Pharma plant.

—— Saad Hashmi

Much better products than others. The performance of HEPA filter is perfect. The quality is as same as AAF and comfil which we used before while with the better cost.

—— Eric Nunes

We wanted two decontamination container for a mine in Finland last year and thanks so much for INDAIR's professional suggestion to avoid the problems during the process. I would choose INDAIR next time!

—— Petteri Viinanen

I'm Online Chat Now

Laboratory Bio Air Sampler 100L / Min Unique Structure Sampling By Low Noise Pump

Laboratory Bio Air Sampler 100L / Min Unique Structure Sampling By Low Noise Pump
Laboratory Bio Air Sampler 100L / Min Unique Structure Sampling By Low Noise Pump

Large Image :  Laboratory Bio Air Sampler 100L / Min Unique Structure Sampling By Low Noise Pump

Product Details:
Place of Origin: China
Brand Name: indair
Certification: ISO,CE
Model Number: ID-FSC-IV
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: negotiable
Packaging Details: CARTON WITH PLASTIC BAG
Supply Ability: 200 UNIT PER DAY
Detailed Product Description
Gross Weight: 6KG Inside: Aluminium Carrying Case
Packing Size: 42*19*38cm Sampling Volume: 100L/min
Power Supply: AC And DC Operating Time On Battery(h): 6-8
High Light:

microbial air sampler

,

micro air sampler

 

Laboratory Instruments Portable Electronic Factory Price Microbiology Air Biological Sampler Experimental

 

Principle:

This microbial air sampler works based on Andersen collision

principle. Air is aspirated (at a fixed speed for variable times) through small holes in the instrument's head. The resulting laminar air flow is directed onto the surface of an agar plate. At the end of the sampling cycle, the plate is removed and incubated and the visible colonies are then counted for an assessment of the level of contamination.

 

How to use:

1: Soak medical absorbent cotton in 75% ethanol, and use it to swab air sampler surface, Petri dish pedestal and sampling head et al.

2: Start the sampler and let it work not less than 5 minutes, making above mentioned disinfector residue evaporate.

3: According to cleanliness requirements to set sampling parameters, then put Petri dish (with medium) inside, and cover the multi-hole sampling head.

4: Put the air sampler on flat surface 0.8-1.5m above the ground, and then start it begin sampling.

 

Main characters:
* Sampling hole has many small holes to reduce puffball superposition and reduce error of animalcule count.
* Programmable, sampling quantity can be set from 0.01 to 6.0 stereos.
* LCD displays sampling quantity, sampling time and other parameters.
*Save sampling quantity, sampling time and other parameters in pages and save 256 pages at most.
* Particular sculpting, convenient to use.
* Simple to exchange substrate utensil, just only take down sampling hole to exchange substrate utensil
(Standard diameter is Φ 90*15)
 

Parameters:
1. Sampling volume: 100L/min;
2. Wind speed of sampling holes: 0.4m/s, basically the same as that of clean room (isokinetic sampling);
3. Power supply: AC and DC;
4. Rechargeable battery: DC 6V;
5. Operating time on battery: 4h;
6. Dimension: 120 x 300 ;
7. Weight: 2kg.

 

Sampling inlet has many tiny holes to reduce puffball superposition and error of animalcule count.
Sampling flow 100L/min
Inlet impact speed

0.38m/s basically the same as the speed of clean room.

(isokinetic sampling)

Sampling quantity can be set from 0.001—9.999m³
Standard dimension of culture dish Φ90*15
Power supply DC16.8V chargeable battery which can supply 4hours power
Dimension Φ120*325
Weight 3.0kg

Laboratory Bio Air Sampler 100L / Min Unique Structure Sampling By Low Noise Pump 0

Q:Can you arrange the visit to your user?Can you customized the machine according to our requirements?
A:Yes,Of course!


Q:Is your equipment in accordance with GMP,FDA,WHO?
A:Yes,we will design and manufacture the equipment according to the requirement of GMP/FDA/WHO in your company.


Q:How about your after sale service?
A:We will reply you within 24hours by email or phone.
If we have local agent,we will arrange him to your site within 24 hours to assist you to shoot the problem.


Q:How about the staff training?
A:Normally,we will train your staffs during the installation in your site,you are also welcome to send your staff train in our factory.


Q:How long will the turnkey project take?
A:About 1 year from designing the layout to finish installation and commissioning.


Q:Which kind of after-sales service you can offer?
A:Except the regular service ,we can also provide you know-how transfer,and dispatch our qualified engineers to help you run the factory up to 6-12 months.

Contact Details